HAMGSM133

V. 02 – 15/05/2012

10

©Velleman nv

Set logic alarm level to LOW (alarm when input tensionless)
Password
Command LIVx:B

x = 1 (input 1) or 2 (input 2)

Example LIV1:B
Result

Set alarm level on input 1 to low, alarm is activated when input 1 loses

tension.

Set logic alarm level to switching (alarm when input tension changes)
Password
Command LIVx:V

x = 1 (input 1) or 2 (input 2)

Example LIV1:V
Result

When tension changes on input 1, e.g. from low to high, the alarm is

activated.

Request logic alarm level
Password
Command LIV?
Example LIV?
Result

Get a list of logic alarm levels on both inputs.

Inhibition time input 1
Password
Command INI1:mm

mm = time in minutes (00~59)

Example INI1:02
Result

After alarm activation, the device will not check the alarm level on input 1 for
2 minutes (inhibition time). Default = 5 minutes

Inhibition time input 2
Password
Command INI2:mm

mm = time in minutes (00~59)

Example INI2:15
Result

After alarm activation, the device will not check the alarm level on input 2 for
15 minutes (inhibition time). Default = 5 minutes

Request inhibition times
Password
Command INI?
Example INI?
Result

Get a list of the inhibition time on both inputs.

Reset inhibition time input 1
Password
Command TIZ1x

x = 0 (no reset) or 1 (reset)

Example TIZ11
Result

Inhibition time reset on input 1 when input 1 is idle. Default = no reset