Velleman HAMGSM133 User Manual
Page 10

HAMGSM133
V. 02 – 15/05/2012
10
©Velleman nv
Set logic alarm level to LOW (alarm when input tensionless)
Password
Command LIVx:B
x = 1 (input 1) or 2 (input 2)
Example LIV1:B
Result
Set alarm level on input 1 to low, alarm is activated when input 1 loses
tension.
Set logic alarm level to switching (alarm when input tension changes)
Password
Command LIVx:V
x = 1 (input 1) or 2 (input 2)
Example LIV1:V
Result
When tension changes on input 1, e.g. from low to high, the alarm is
activated.
Request logic alarm level
Password
Command LIV?
Example LIV?
Result
Get a list of logic alarm levels on both inputs.
Inhibition time input 1
Password
Command INI1:mm
mm = time in minutes (00~59)
Example INI1:02
Result
After alarm activation, the device will not check the alarm level on input 1 for
2 minutes (inhibition time). Default = 5 minutes
Inhibition time input 2
Password
Command INI2:mm
mm = time in minutes (00~59)
Example INI2:15
Result
After alarm activation, the device will not check the alarm level on input 2 for
15 minutes (inhibition time). Default = 5 minutes
Request inhibition times
Password
Command INI?
Example INI?
Result
Get a list of the inhibition time on both inputs.
Reset inhibition time input 1
Password
Command TIZ1x
x = 0 (no reset) or 1 (reset)
Example TIZ11
Result
Inhibition time reset on input 1 when input 1 is idle. Default = no reset