beautypg.com

Velleman HAMGSM133 User Manual

Page 11

background image

HAMGSM133

V. 02 – 15/05/2012

11

©Velleman nv

Reset inhibition time input 2
Password
Command TIZ2x

x = 0 (no reset) or 1 (reset)

Example TIZ20
Result

Inhibition time does not reset on input 2 when input 2 is idle. Default = no

reset

Request status of reset function
Password
Command INI?
Example INI?
Result

Receive the status of the reset function on the inputs.

Alarm condition time-out input 1
Password
Command OSS1:ss

ss = time in seconds (00~59)

Example OSS:08
Result

The alarm on input 1 must remain for 8 seconds before the alarm is passed
on. Default = 1 second

Alarm condition time-out input 2
Password
Command OSS2:ss

ss = time in seconds (00~59)

Example OSS2:15
Result

The alarm on input 2 must remain for 15 seconds before the alarm is passed
on. Default = 1 second

Request alarm condition time-outs
Command OSS?
Example OSS?
Result

Get a list of the alarm condition time-outs on both inputs.

Alarm SMS content when input 1 tension is high
Password
Command TIN1A:xxxxxxxx

xxxxxxxx = message (max. 100 characters, all capitals)

Example

TIN1A: TENSION ON INPUT 1

Result

When tension is detected on input 1, an SMS is sent out with text “TENSION

ON INPUT 1”. Default: ALARM! INPUT 1 HIGH

Note:

a semi colon (;) is not allowed inside the message

Alarm SMS content when input 1 tension is low
Password
Command TIN1B:xxxxxxxx

xxxxxxxx = message (max. 100 characters, all capitals)

Example

TIN1B1: NO TENSION ON INPUT 1

Result

When no tension is detected on input 1, an SMS is sent out with text “NO

TENSION ON INPUT 1”. Default: ALARM! INPUT 1 LOW

Note:

a semi colon (;) is not allowed inside the message