beautypg.com

Programming hints – Velleman HAA2850 User Manual

Page 12

background image

HAA2850

v4 - 15.11.2013

12

©Ve lleman nv

notifying beep disabled and replaced by 2 short successful
code entry beeps for valid user codes

User code entry mode (only applicable in multi-user mode)

auto entry mode selected;

is not required after entering

user code (user codes must have the same length as the
master code)(default for single-user mode)

manual entry mode selected;

is required after entering

user code (user codes length can differ from the master
code length) (default for multi-user mode)

Key-press acknowledge tones

key-press tones enabled (default)

key-press tones disabled

Door open time-out

0

no door-open time-out (default)

1 ~ 999

alarm will be triggered when the door remains open
longer than the set time (1~999s)

exit programming mode

information is saved and the keypad returns to normal working mode

Note: in case an error was made during programming, press the

button,

or simply wait for 10s and try again.

9.

Programming hints

single-user vs. multi-user mode

In single-user mode every output can be controlled by only one 4-digit
user code. User codes are stored in memory location and . Default
the -confirmation is not required after entering the user code (auto-
entry mode).

In multi-user mode, up to 100 user codes can be assigned to control
output 1 and up to 10 to control output 2. These user codes can consist
of 4 to 8 digits and the -confirmation button must be pressed after
entering the code (manual entry mode). Before setting to auto-entry
mode, all user codes must have the same length as the master code
(between 4 and 8 digits).

Duress code

User code 1 in single-user mode and all user codes of group 1 in multi-
user mode come with a duress code function. This duress code is