C&H Technology PM1200HCE330-1 User Manual
Page 5

3
PM1200HCE330-1
High Voltage Intelligent Power Module
1200 Amperes/3300 Volts
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
ElectricalCharacteristics,
T
j
= 25
°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ.
Max.
Units
Control Part
Supply Voltage
V
D
Applied between V
1
~ V
C
21.6
24.0
26.4
Volts
Circuit Current
I
D
V
D
= 24V, T
j
= 25
°
C
—
80
120
mA
Input ON Threshold Voltage
V
th(on)
Applied between C
1
~ V
C
6.1
6.7
7.3
Volts
Input OFF Threshold Voltage
V
th(off)
10.5
11.1
11.7
Volts
Minimum Fault Output Pulse Width
t
FO
V
D
= 24V
—
100
200
µ
s
Overcurrent Trip Level
OC
T
j
= -25
°
C ~ 125
°
C
2200
—
—
Amperes
Overtemperature Protection
OT
Trip Level
103
113
123
°
C
(Baseplate Temperature Detection)
OT
r
Reset Level
88
98
108
°
C
Supply Circuit Undervoltage Protection
UV
Trip Level
19.2
20.0
20.8
Volts
(T
j
= -25
°
C ~ 125
°
C)
UV
r
Reset Level
—
20.5
—
Volts
Inverter Part
Collector-Emitter Saturation Voltage
V
CE(sat)
I
C
= 1200A, T
j
= 25
°
C
—
3.05
3.97
Volts
FWDi Forward Voltage
V
EC
-I
C
= 1200A, T
j
= 25
°
C
—
2.90
3.77
Volts
Collector Cutoff Current
I
CES
V
CE
= V
CES
, T
j
= 25
°
C
—
—
15
mA
V
CE
= V
CES
, T
j
= 125
°
C
—
—
60
mA