C&H Technology PM15CZF120 User Manual
Page 4

507
PM15CZF120
Intellimod™ Modules
Three Phase Converter IGBT Inverter Output
15 Amperes/1200 Volts
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Electrical and Mechanical Characteristics,
T
j
= 25
°
C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ.
Max.
Units
Control Sector
Over Current Trip Level
OC
-20
°
C
≤
T
j
≤
125
°
C, V
D
= 15V
22
37
–
Amperes
Short Circuit Trip Level
SC
-20
°
C
≤
T
j
≤
125
°
C, V
D
= 15V
–
56
–
Amperes
Over Current Delay Time
t
off(OC)
V
D
= 15V
–
10
–
µ
S
Over Temperature Protection
OT
Trip Level
100
110
120
°
C
OT
R
Reset Level
–
90
–
°
C
Supply Circuit Under Voltage Protection
UV
Trip Level
11.5
12.0
12.5
Volts
UV
R
Reset Level
–
12.5
–
Volts
Supply Voltage
V
D
Applied between V
UP1
-V
UPC
,
13.5
15.0
16.5
Volts
V
VP1
-V
VPC
, V
WP1
-V
WPC
, V
N1
-V
NC
Circuit Current
I
D
V
D
= 15V, V
CIN
= 15V, V
N1
-V
NC
–
18
25
mA
V
D
= 15V, V
CIN
= 15V, V
XP1
-V
XPC
–
7
10
mA
Input ON Threshold Voltage
V
CIN(on)
Applied between
1.2
1.5
1.8
Volts
Input OFF Threshold Voltage
V
CIN(off)
U
P
, V
P
, W
P
, U
N
, V
N
, W
N
1.7
2.0
2.3
Volts
PWM Input Frequency
f
PWM
3-Ø Sinusoidal
–
15
20
kHz
Fault Output Current
I
FO(H)
V
D
= 15V, V
FO
= 15V
–
–
0.01
mA
I
FO(L)
V
D
= 15V, V
FO
= 15V
–
10
15
mA
Minimum Fault Output Pulse Width
t
FO
V
D
= 15V
1.0
1.8
–
mS