Measuring cell), 11 supplement – VEGA VEGABAR 83 4 … 20 mA_HART - Operating Instructions User Manual
Page 85
85
11 Supplement
VEGABAR 83 • 4 … 20 mA/HART
45034-EN-131010
VEGABAR 83, flange connection 180 °C/200 °C (METEC
®
measuring cell)
5.91"
6.50"
7.87"
40
40
50
40
80
40
9.25"
100
40
150
40
6.50"
50
40
DN
mm
inch
PN
D
k
b
d2
d4
f
RL
d5
A8
40
40
150
18
110
B2
B5
50
40
165
20
125
4xø18
4xø18
88
102
3
3
CD
100
40
235
24
190
8xø22
162
3
80
40
200
24
160
8xø18
138
3
-
-
-
-
1
4
4
..
150
40
300
28
250
8xø26
218
3
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
LC
50
40
165
20
125
4xø18
102
3
38
CA
2“ 150 lbs
CB
3“ 150 lbs
2
3.62"
4xø 0.75"
4.75"
0.77"
7.48"
4xø 0.75"
6“
5“
5.91"
0.71"
11.81"
0.79"
0.95"
0.95"
1.10"
0.79"
4.33"
4.92"
6.30"
7.48"
9.84"
4.92"
4xø 0.71"
4xø 0.71"
4xø 0.71"
8xø 0.71"
8xø 0.87"
8xø 1.02"
3.47"
4.02"
5.43"
6.38"
8.58"
4.02"
0.12"
0.12"
0.12"
0.12"
0.12"
0.12"
1.50"
A8
B2
B5
CD
..
LC
0.12"
0.12"
0.96"
4
3
LC
A8, B2, B5, CD, ..
121 mm (4.76")
82 mm (3.23")
d4
k
D
f
b
d2
RL
d5
Fig. 57: VEGABAR 83, flange connection
1 Flange connection according to DIN 2501
2 Flange connection according to ASME B16,5
3 Temperature adapter up to 180 °C
4 Temperature screen sheet up to 200 °C
- VEGABAR 25 (24 pages)
- VEGAFLEX 55K (32 pages)
- VEGABAR 17 (36 pages)
- D80 Hydrostatic pressure transmitters (40 pages)
- VEGAMET 513 (52 pages)
- D81 Hydrostatic pressure transmitter (44 pages)
- VEGASTAB 690 (12 pages)
- VEGASWING 83 fail safe and signal conditioning instrument VEGATOR 526 Ex (28 pages)
- VEGACONNECT 2 (4 pages)
- D81 METEC Hydrostatic pressure transmitter (44 pages)
- VEGAPULS 45 4 … 20 mA; HART compact sensor (72 pages)
- VEGAMET 515 (68 pages)
- VEGAFLEX 52K (32 pages)
- Capacitive electrodes EK Profibus PA (56 pages)
- VEGATOR 631 S1 (4 pages)
- VEGAPULS 63 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART - two-wire (68 pages)
- Capacitive electrodes EK 4 … 20 mA - Compact (40 pages)
- VEGABAR 65 4 … 20 mA_HART (76 pages)
- VEGABAR 64 Profibus PA (80 pages)
- VEGABAR 44 4 … 20 mA (28 pages)
- VEGADIS 50 Ex (8 pages)
- VEGAPULS 51V…54V (96 pages)
- VEGAFLEX 54P (Profibus PA) (48 pages)
- VEGASEL 643 (16 pages)
- VEGAPULS 56K (68 pages)
- VEGAFLEX 54K (36 pages)
- VEGABAR 41 HART (44 pages)
- VEGATOR 537 Ex (16 pages)
- VEGACAP 82-98 (36 pages)
- VEGADIS 371 Ex (20 pages)
- Capacitive electrodes EL Profibus PA (56 pages)
- VEGAFLEX 52V (36 pages)
- VEGAFLEX 51K (32 pages)
- VEGALOG 571 EP (Ex) (32 pages)
- D84 Hydrostatic pressure transmitter (44 pages)
- VEGABAR 64 Foundation Fieldbus (80 pages)
- VEGABAR 61 4 … 20 mA_HART (80 pages)
- VEGASCAN 850 (92 pages)
- VEGASON 54P…56P Profibus PA (68 pages)
- D77 Hydrostatic pressure transmitters (24 pages)
- VEGATRENN 546 Safety barrier type 146 (8 pages)
- VEGASON 71 - 1 … 75 - 1 (52 pages)
- VEGABAR 40 HART (40 pages)
- Capacitive electrodes EL … (44 pages)
- VEGABAR 24 (28 pages)