VEGA VEGAFLEX 83 4 … 20 mA_HART two-wire Rod probe - Polished version With SIL qualification User Manual
Page 80
80
12 Supplement
VEGAFLEX 83 • 4 … 20 mA/HART two-wire
44225-EN-130823
L
2 mm
(0.079
")
0
-2 mm
(-0.079
")
15 mm
(0.591
"
)
-15 mm
(-0.591
"
)
-10 mm
(-0.394
")
0,35 m
(13.78
")
0,15 m
(5.906
"
)
0,1 m
(3.937
")
0,05 m
(1.969
")
1
1
Fig. 45: Deviation VEGAFLEX 83 in rod version in oil
1 Dead band - no measurement possible in this area
L Probe length
Repeatability
≤ ±1 mm
Specification for safety accuracy (SIL)
Siehe Safety Manual
Variables influencing measurement accuracy
Specifications for the digital measured value
Temperature drift - Digital output
±3 mm/10 K relating to the max. measuring range or
max. 10 mm (0.394 in)
Additional deviation through electromag-
netic interference acc. to EN 61326
< ±10 mm (< ±0.394 in)
Specifications apply also to the current output
8)
Temperature drift - Current output
±0.03 %/10 K relating to the 16 mA span max. ±0.3 %
Deviation on the current output through
analogue/digital conversion
< ±15 µA
Additional deviation through electromag-
netic interference acc. to EN 61326
< ±150 µA
Influence of the superimposed gas and pressure to the accuracy
The propagation speed of the radar impulses in gas or vapour above the medium is reduced by
high pressure. This effect depends on the superimposed gas or vapour and is especially large at
low temperatures.
The following table shows the resulting deviation for some typical gases and vapours. The specified
values refer to the distance. Positive values mean that the measured distance is too large, negative
values that the measured distance is too small.
8)
Also for the second current output (optional)