6 Set up with the display and adjustment module
SOLITRAC 31 • Profibus PA
43834-EN-131119
The SOLITRAC 31 requires this information for the decay compensa-
tion. An annual recalibration is hence not necessary.
Enter the requested parameters via the appropriate keys, save your
settings with [OK] and jump to the next menu item with the [ESC] and
the [->] key.
Enter here, the respective application.
This menu item enables adaptation of the sensor to the requested ap-
plication. You can choose between the following applications: "Level",
"Point level" or "Summation Slave".
In this menu item you can activate the function of the current output.
When the output is activated, the instrument remains in its function as
a Slave, but the 4 … 20 mA output of the SOLITRAC 31 can be also
used als single instrument.
When the output is active, the instrument has the complete function-
ality of a level measuring instrument. In this case, continue reading
under "Parameter adjustment/Level measurement".
Since the adjustment is very comprehensive, the menu points of
Function Blocks 1 (FB1) were put together in a submenu.
In menu item"Channel" you determine which measured value the
output refers to.
In menu item "Scaling unit" you define the scaling variable and the
scaling unit for the pulse rate on the display, e.g. volume in percent.
Setup - Application
Setup - Outputs
Setup - AI FB1
Setup - AI FB1 - Channel
Setup - AI FB1 - Scaling
unit