12 Supplement
VEGAFLEX 81 • 4 … 20 mA/HART two-wire
44216-EN-130823
Ʋ Pipe thread, cylindrical (ISO 228 T1) G1½ according to DIN 3852-A
Ʋ American pipe thread, conical
(ASME B1.20.1)
1½ NPT
Ʋ Flanges
DIN from DN 50, ANSI from 2"
Weight
Ʋ Instrument weight (depending on
process fitting)
approx. 0.8 … 8 kg (0.176 … 17.64 lbs)
Ʋ Tube: ø 21.3 mm (0.839 in)
approx. 1110 g/m (11.9 oz/ft)
Ʋ Tube: ø 42.2 mm (1.661 in)
approx. 3100 g/m (33.3 oz/ft)
Probe length L (from seal surface)
Ʋ Tube: ø 21.3 mm (0.839 in)
up to 6 m (19.69 ft)
Ʋ Tube: ø 42.2 mm (1.661 in)
up to 6 m (19.69 ft)
Ʋ Trimming accuracy - tube
±1 mm
Lateral load
Ʋ Tube: ø 21.3 mm (0.839 in)
60 Nm (44 lbf ft)
Ʋ Tube: ø 42.2 mm (1.661 in)
300 Nm (221 lbf ft)
Torque for NPT cable glands and Conduit tubes
Ʋ Plastic housing
max. 10 Nm (7.376 lbf ft)
Ʋ Aluminium/Stainless steel housing
max. 50 Nm (36.88 lbf ft)
Input variable
Measured variable
Level of liquids
Min. dielectric constant of the medium
ε
r
≥ 1.4
- VEGABAR 25 (24 pages)
- VEGAFLEX 55K (32 pages)
- VEGABAR 17 (36 pages)
- D80 Hydrostatic pressure transmitters (40 pages)
- VEGAMET 513 (52 pages)
- D81 Hydrostatic pressure transmitter (44 pages)
- VEGASTAB 690 (12 pages)
- VEGASWING 83 fail safe and signal conditioning instrument VEGATOR 526 Ex (28 pages)
- VEGACONNECT 2 (4 pages)
- D81 METEC Hydrostatic pressure transmitter (44 pages)
- VEGAPULS 45 4 … 20 mA; HART compact sensor (72 pages)
- VEGAMET 515 (68 pages)
- VEGAFLEX 52K (32 pages)
- Capacitive electrodes EK Profibus PA (56 pages)
- VEGATOR 631 S1 (4 pages)
- VEGAPULS 63 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART - two-wire (68 pages)
- Capacitive electrodes EK 4 … 20 mA - Compact (40 pages)
- VEGABAR 65 4 … 20 mA_HART (76 pages)
- VEGABAR 64 Profibus PA (80 pages)
- VEGABAR 44 4 … 20 mA (28 pages)
- VEGADIS 50 Ex (8 pages)
- VEGAPULS 51V…54V (96 pages)
- VEGAFLEX 54P (Profibus PA) (48 pages)
- VEGASEL 643 (16 pages)
- VEGAPULS 56K (68 pages)
- VEGAFLEX 54K (36 pages)
- VEGABAR 41 HART (44 pages)
- VEGATOR 537 Ex (16 pages)
- VEGACAP 82-98 (36 pages)
- VEGADIS 371 Ex (20 pages)
- Capacitive electrodes EL Profibus PA (56 pages)
- VEGAFLEX 52V (36 pages)
- VEGAFLEX 51K (32 pages)
- VEGALOG 571 EP (Ex) (32 pages)
- D84 Hydrostatic pressure transmitter (44 pages)
- VEGABAR 64 Foundation Fieldbus (80 pages)
- VEGABAR 61 4 … 20 mA_HART (80 pages)
- VEGASCAN 850 (92 pages)
- VEGASON 54P…56P Profibus PA (68 pages)
- D77 Hydrostatic pressure transmitters (24 pages)
- VEGATRENN 546 Safety barrier type 146 (8 pages)
- VEGASON 71 - 1 … 75 - 1 (52 pages)
- VEGABAR 40 HART (40 pages)
- Capacitive electrodes EL … (44 pages)
- VEGABAR 24 (28 pages)