11 Supplement
VEGAPULS 65 • Modbus and Levelmaster protocol
41365-EN-121011
Process conditions
For the process conditions, please also note the specifications on the type label. The lower value
always applies.
Process temperature (measured on the process fitting)
Ʋ Process fitting, thread PVDF
-40 … +130 °C (-40 … +266 °F)
Ʋ Other process fittings
-40 … +150 °C (-40 … +302 °F)
Vessel pressure
Ʋ Screwed part PVDF
-1 … 2 bar (-100 … 200 kPa/-14.5 … 29.0 psig)
Ʋ Screwed part and flange 316L
-1 … 16 bar (-100 … 1600 kPa/-14.5 … 232 psig)
Vessel pressure relating to the flange
nominal stage
see supplementary instructions manual "Flanges ac-
cording to DIN-EN-ASME-JIS"
Vibration resistance
4 g at 5 … 200 Hz according to EN60068-2-6 (vibration
with resonance)
Shock resistance
100 g, 6 ms according to EN 60068-2-27 (mechanical
shock)
Electromechanical data - version IP 66/IP 67
Options of the cable entry
Ʋ Cable gland
M20 x 1.5 (cable: ø 5 … 9 mm)
Ʋ Cable entry
½ NPT
Ʋ Blind stopper
M20 x 1.5; ½ NPT
Ʋ Closing cap
M20 x 1.5; ½ NPT
Plug options
Ʋ Supply and signal circuit (only with low
voltage)
M12 x 1
Ʋ Indication circuit
M12 x 1
Wire cross-section (spring-loaded terminals)
Ʋ Massive wire, cord
0.2 … 2.5 mm² (AWG 24 … 14)
Ʋ Stranded wire with end sleeve
0.2 … 1.5 mm² (AWG 24 … 16)
Indicating and adjustment module
Voltage supply and data transmission
through the sensor
Indication
LC display in dot matrix
Measured value indication
Ʋ Number of digits
5
Ʋ Size of digits
W x H = 7 x 13 mm
Adjustment elements
4 keys
Protection rating
Ʋ unassembled
IP 20
Ʋ mounted into the sensor without cover IP 40
Materials
Ʋ Housing
ABS
Ʋ Inspection window
Polyester foil