beautypg.com

VEGA VEGASOURCE 31 User Manual

Page 32

background image

32

6 Setup

VEGASOURCE 31 •

38131-EN-130415

180°

1

3

6

3

4

5

2

2

1

Fig. 24: Switching the radiation on - VEGASOURCE 31 version B
1 Padlock

2 Locking screw

3 Fixing pin

4 Safety catch

5 Holding pin

6 Swivel bracket

Initial situation: Source holder is in position OFF

Remove padlock (1)

Loosen locking screw (2)

Pull out fixing pin (3)

Warning:

Do not remove the safety catch (4). Do not remove the seal. Do not

push the sealed pin (5). Turning the insert above the pin (5) leads to

the removal position of the source insert.

Turn stirrup (6) 180° anticlockwise

Note:

The actual switch position is shown by the visible label (ON or OFF).

The other label is always covered by the stirrup (6).

Let the fixing pin (3) snap in in position ON. Check if it snaps in

correctly

Fasten the padlock (1) in the specified position on the securing bar

(4) until it is required again

Tighten locking screw (2)

Radiation ON

The label EIN - ON is visible. The marking arrow points to EIN - ON.
Radiation OFF

The label AUS - OFF is visible. The marking arrow points to AUS -

OFF.

Indication of the switch-

ing status