beautypg.com

VEGA VEGASOURCE 31 User Manual

Page 26

background image

26

4 Mounting

VEGASOURCE 31 •

38131-EN-130415

The source holder must be integrated in the potential equalization of

the system.
To ensure a reliable electrical contact between the source container

and the mounting bracket, the supplied lock washers must be used

according to the following illustration.
Use the prescribed torque for the mounting screws. Make sure that

the screws have electrical contact to the potential equalization.
You can find the torques of the mounting screws in chapter "Technical

data".

1

1

Fig. 19: Lock washers as untwist guard and conductive connection to the

potential equalization
1 Lock washers (2 pcs.)

The source container can also be mounted, for example, on a mount-

ing plate provided by the customer or on an L-profile.

120 mm

(4.7")

D

C

A

8x45°

D

B

B

1

2

Fig. 20: Mounting facility supplied by the customer
1 Mounting plate

2 L-profiles

EN

ANSI

A

68.9 mm (2.71 in)

72.9 mm (2.87 in)

B

166.3 mm (6.55 in)

176.0 mm (6.93 in)

C

180.0 mm (7.09 in)

190.5 mm (7.50 in)

D

18.0 mm (0.71 in)

19.1 mm (0.75 in)

The mounting flange of VEGASOURCE 31 is compatible with:

DN 100 PN 16

ANSI 4" 150 lbs

Untwist guard

Mounting facilities