VEGA VEGASOURCE 31 User Manual
Page 26
26
4 Mounting
VEGASOURCE 31 •
38131-EN-130415
The source holder must be integrated in the potential equalization of
the system.
To ensure a reliable electrical contact between the source container
and the mounting bracket, the supplied lock washers must be used
according to the following illustration.
Use the prescribed torque for the mounting screws. Make sure that
the screws have electrical contact to the potential equalization.
You can find the torques of the mounting screws in chapter "Technical
data".
1
1
Fig. 19: Lock washers as untwist guard and conductive connection to the
potential equalization
1 Lock washers (2 pcs.)
The source container can also be mounted, for example, on a mount-
ing plate provided by the customer or on an L-profile.
120 mm
(4.7")
D
C
A
8x45°
D
B
B
1
2
Fig. 20: Mounting facility supplied by the customer
1 Mounting plate
2 L-profiles
EN
ANSI
A
68.9 mm (2.71 in)
72.9 mm (2.87 in)
B
166.3 mm (6.55 in)
176.0 mm (6.93 in)
C
180.0 mm (7.09 in)
190.5 mm (7.50 in)
D
18.0 mm (0.71 in)
19.1 mm (0.75 in)
The mounting flange of VEGASOURCE 31 is compatible with:
•
DN 100 PN 16
•
ANSI 4" 150 lbs
Untwist guard
Mounting facilities