C

able entry housing

1

x cable gland M20 x 1.5 (cable: ø 5 … 9 mm), 1 x

blind stopper M20 x 1.5

S

crew terminals for cable cross-section up to

1.5

mm² (AWG 16)

Voltage supply

O

perating voltage

9.6 … 36 V DC

P

ermissible residual ripple

-

<

100 H

z

U

ss

<

1 V

-

100 H

z … 10 kHz

U

ss

<

10

mV

L

oad

see diagram

1200

880

600

380

12

18

16

9,6

14

20

22

24

26

28 29 30

32

34

36

V

1

4

2

3

Fig. 17: Voltage diagram

1

HART load

2

Voltage limit Ex ia

3

Voltage limit non-Ex

4

Operating voltage

Integrated overvoltage protection

N

ominal leakage current (8/20 µs)

5

kA

M

in. response time

<

25

ns

Electrical protective measures

P

rotection rating

-

T

ransmitter

IP

68 (30

bar)

-

H

ousing

IP

66/IP 67

O

vervoltage category

III

P

rotection class

III

Approvals

I

nstruments with approvals can have different technical data depending on the version.

36

VEGAWELL

52 • 4 … 20

mA/HART Pt

10 S

upplement

35402

-EN

-111021