3 wiring plan – VEGA VEGAWELL 52 4 … 20 mA_HART Pt 100 User Manual
Page 18
10 S
crew the housing cover on
T
he electrical connection is finished.
P
roceed as follows:
1
U
nscrew the housing cover
2
I
nsert the connection cable through the cable entry into the plastic
housing
3
L
oosen the screws with a screwdriver
4
I
nsert the wire ends into the open terminals according to the wiring
plan
5
T
ighten the screws with a screwdriver
6
C
heck the hold of the wires in the terminals by lightly pulling on
them
7
T
ighten the compression nut of the cable entry. The seal ring must
completely encircle the cable
8
R
etighten the housing cover
T
he electrical connection is finished.
5
.3 Wiring plan
1
8
2
3
4
5
6
7
Fig. 8: Wire assignment connection cable
1
Brown (+): to power supply or to the processing system
2
Blue (-): to power supply or to the processing system
3
White: for processing of the integrated Pt 100 (power supply)
4
Yellow: for processing of the integrated Pt 100 (measurement)
5
Red: for processing of the integrated Pt 100 (measurement)
6
Black: for processing of the integrated Pt 100 (power supply)
7
Shielding
8
Breather capillaries with filter element
Connection via housing
Direct connection
18
VEGAWELL
52 • 4 … 20
mA/HART Pt
5 C
onnecting to power supply
35402
-EN
-111021