beautypg.com

3 wiring plan – VEGA VEGAWELL 52 4 … 20 mA_HART Pt 100 User Manual

Page 18

background image

10 S

crew the housing cover on

T

he electrical connection is finished.

P

roceed as follows:

1

U

nscrew the housing cover

2

I

nsert the connection cable through the cable entry into the plastic

housing

3

L

oosen the screws with a screwdriver

4

I

nsert the wire ends into the open terminals according to the wiring

plan

5

T

ighten the screws with a screwdriver

6

C

heck the hold of the wires in the terminals by lightly pulling on

them

7

T

ighten the compression nut of the cable entry. The seal ring must

completely encircle the cable

8

R

etighten the housing cover

T

he electrical connection is finished.

5

.3 Wiring plan

1

8

2

3

4

5

6

7

Fig. 8: Wire assignment connection cable

1

Brown (+): to power supply or to the processing system

2

Blue (-): to power supply or to the processing system

3

White: for processing of the integrated Pt 100 (power supply)

4

Yellow: for processing of the integrated Pt 100 (measurement)

5

Red: for processing of the integrated Pt 100 (measurement)

6

Black: for processing of the integrated Pt 100 (power supply)

7

Shielding

8

Breather capillaries with filter element

Connection via housing

Direct connection

18

VEGAWELL

52 • 4 … 20

mA/HART Pt

5 C

onnecting to power supply

35402

-EN

-111021