beautypg.com

3 shorten suspension cable – VEGA VEGAWELL 52 4 … 20 mA_HART Pt 100 User Manual

Page 27

background image

?

4 … 20

mA signal not stable

l

L

evel fluctuations

à Adjust integration time via PACTware

l

no atmospheric pressure compensation

à Check the capillaries and cut them clean
à Check the pressure compensation in the housing and clean

the filter element, if necessary

?

4 … 20

mA signal missing

l

C

onnection to voltage supply wrong

à Check connection according to chapter "Connection steps"

and if necessary, correct according to chapter "Wiring plan"

l

N

o power supply

à Check cables for breaks; repair if necessary

l

O

perating voltage too low or load resistance too high

à Check, adapt if necessary

?

C

urrent signal 3.6 mA; 22 mA

l

electronics module or measuring cell defective

à Exchange the instrument or send it in for repair

I

n Ex applications, the regulations for the wiring of intrinsically safe

circuits must be observed.

D

epending on the reason for the fault and the measures taken, the

steps described in chapter "Set up" may have to be carried out again.

8

.3 Shorten suspension cable

S

horten the suspension cable individually. Proceed as follows:

1

R

emove the filter adapter from the transparent capillary line

2

C

ut the suspension cable with an edge cutter to the requested

length

Caution:
D

o not squeeze the capillary cable, this will influence the pressure

compensation. If necessary, rework with a sharp knife.

3

R

emove approx. 10 cm of the cable mantle, strip off approx. 1 cm

of the wire ends

I

nsert the filter adapter

T

he work steps are finished.

Reaction after fault rec-
tification

VEGAWELL

52 • 4 … 20

mA/HART Pt

27

8 M

aintenance and fault rectification

35402

-

EN

-111021