6 Adjustment with the display and adjustment module PLICSCOM
VEGADIF 65 • Profibus PA
36129-EN-130417
•
Linearization curve
•
Leak flow volume suppression
•
Sensor-TAG
•
Displayed value
•
Scaling unit (Out-Scale unit)
•
Positions after the decimal point (scaled)
•
Scaling PA/Out-Scale 4 values
•
Unit of measurement
•
Language
The following safety-relevant data are not read out or written:
•
Sensor address
•
PIN
Copy sensor data
Copy sensor data?
Basic adjustment
The reset "Basic adjustment" resets the following menu items to the
reset values (see chart):
Menu section
Menu item
Reset value
Basic settings
Zero/Min. adjustment
Measuring range begin
Span/Max. adjustment
Measuring range end
Density
1 kg/l
Density unit
kg/l
Damping
1 s
Linearization
Linear
Sensor-TAG
Sensor
Display
Displayed value
PA-Out
Diagnostics
Totalizer
0.0000 10
00
gal
Part sum counter
0.0000 10
00
gal
Service
Additional PA value
Secondary Value 1
Out-Scale-Unit
Volume/l
Scaling
0.00 to 100.0
Decimal point indication 8888.8
The values of the following menu items are not reset with "Reset:
Menu section
Menu item
Reset value
Basic settings
Unit of measurement
bar
Temperature unit
°C
Position correction
No reset
Display
Backlight
No reset
Reset