4 Mounting

VEGADIF 65 • Profibus PA

36129-EN-130417

+ –

2

1

Fig. 11: Marking for plus/minus side on the process component
1 Plus side

2 Minus side

The following illustration shows the elements for a tube mounting and

an example for a mounting arrangement with valve block.

2 3 4

6

7

8

9

10

1

5

Fig. 12: Mounting arrangement with tube mounting
1 Strap for tube mounting

2 Mounting bracket

3 Ventilation valve

4 Fixing screws

5 VEGADIF 65

6 PTFE seal

7 Valve block

8 Oval flange adapter

9 Fixing screws

10 Effective pressure line

Valve blocks enable the simple installation and setup of the differential

pressure transmitter. They separate the pressure transmitter from the

process side and enable also a check of the measurement loop. They

are available as 3-fold and 5-fold version. The integrated equalization

valve enables a pressure compensation between plus and minus side

Mounting arrangement

Valve blocks