10 Supplement
VEGABAR 66 • Profibus PA
36739-EN-130321
Ʋ with measuring ranges 0.1 bar
(1.45 psig) or 0.2 bar (2.9 psig)
max. 15 bar (217.6 psig) or max. 20 bar (290 psig)
12)
Ʋ with meas. ranges from 0.4 bar
(5.8 psig)
max. 25 bar (363 psig)
13)
Pressure stage, process fitting
Ʋ Threaded fitting
316L PN 3, PVDF PN 5
14)
Ʋ Thread
316L PN 25, PVDF unpressurized
Ʋ Lock fitting
Unpressurized
Ʋ Flange 316L
PN 16 or PN 40
Ʋ Flange GFK
10 bar
Product temperature, suspension cable/measuring cell seal
Ʋ PE/FKM
-20 … +60 °C (-4 … +140 °F)
Ʋ PE/EPDM
-20 … +60 °C (-4 … +140 °F)
Ʋ PUR/FKM
-20 … +80 °C (-4 … +176 °F)
Ʋ PUR/EPDM
-20 … +80 °C (-4 … +176 °F)
Ʋ FEP/FKM
-20 … +100 °C (-4 … +212 °F)
Ʋ FEP/FFKM
-10 … +100 °C (+14 … +212 °F)
Ʋ FEP/EPDM
-20 … +100 °C (-4 … +212 °F)
Product temperature, connection tube/seal meas. cell
Ʋ FKM
-20 … +100 °C (-4 … +212 °F)
Ʋ FFKM
-10 … +100 °C (+14 … +212 °F)
Ʋ EPDM
-20 … +100 °C (-4 … +212 °F)
Product temperature, transmitter protection/seal meas. cell
Ʋ PVDF/FKM or EPDM
-20 … +60 °C (-4 … +140 °F)
Ʋ PVDF/FFKM
-10 … +60 °C (+14 … +140 °F)
Ʋ PE/FKM or EPDM
-20 … +60 °C (-4 … +140 °F)
Calibration position
upright, diaphragm points downward
Influence of the installation position
< 0.2 mbar/20 Pa (0.003 psig)
Vibration resistance
mechanical vibrations with 4 g and 5 … 100 Hz
15)
With version with connection tube, vibration resistance 1 g. With lengths > 0.5 m (1.64 ft) the tube
must be supported in addition.
Shock resistance
Acceleration 100 g/6 ms
16)
Electromechanical data - version IP 66/IP 67
Cable entry/plug
17)
12)
Limited by the overpressure resistance of the measuring cell.
13)
Limitation by the pressure-tightness of the cable connection.
14)
Limited by the overpressure resistance of the measuring cell.
15)
Tested according to the guidelines of German Lloyd, GL directive 2.
16)
Tested according to EN 60068-2-27.
17)
Depending on the version M12 x 1, according to ISO 4400, Harting, 7/8" FF.