beautypg.com

10 supplement, 1 technical data – VEGA VEGABAR 66 Profibus PA User Manual

Page 52

background image

52

10 Supplement

VEGABAR 66 • Profibus PA

36739-EN-130321

10 Supplement

10.1 Technical data

General data
Measured variable

Level

Measuring principle

Ceramic-capacitive, dry measuring cell

Communication interface

I²C bus

Materials and weights
Material 316L corresponds to 1.4404 or 1.4435
Materials, wetted parts

Ʋ Transmitter

316L, PVDF

Ʋ Transmitter protection (optional)

PE

Ʋ Diaphragm

sapphire ceramic

®

(99.9 % oxide ceramic)

Ʋ Joining material diaphragm/Basic ele-

ment measuring cell

Glass solder

Ʋ Suspension cable

PE (KTW-approved), FEP, PUR

Ʋ Connection tube

316L

Ʋ Process fitting

316L, PVDF

Ʋ Measuring cell seal

FKM (VP2/A) - FDA and KTW approved, FFKM

(Kalrez 6375), EPDM (A+P 75.5/KW75F)

Ʋ Seal, suspension cable

FKM, FEP

Ʋ Protective cap

PFA

Material seal process fitting

Ʋ Thread G1½ (DIN 3852-A)

Klingersil C-4400

Ʋ Threaded fitting

Klingersil C-4400

Ʋ Lock fitting

Klingersil C-4400

Materials, non-wetted parts

Ʋ Straining clamp

1.4301

Ʋ Threaded fitting

316L, PVDF

Ʋ Lock fitting

316L, PVDF

Ʋ Housing

Plastic PBT (polyester), Alu die-casting powder-coated,

316L

Ʋ External housing

plastic PBT (Polyester), 316L

Ʋ Socket, wall mounting plate external

housing

plastic PBT (Polyester), 316L

Ʋ Seal between housing socket and wall

mounting plate

TPE (fixed connected)

Ʋ Seal between housing and housing

cover

NBR (stainless steel housing), silicone (Alu/plastic hous-

ing)

Ʋ Inspection window in housing cover

for PLICSCOM

Polycarbonate (UL-746-C listed)

Ʋ Ground terminal

316Ti/316L