VEGA VEGADIF 55 Service instructions User Manual
Page 24
Serial
no.
Order no.
Description
55
52020489
Aluminium housing, M20 x 1,5; Profibus PA/Foundation Fieldbus, with key for
adjustment from outside, not for EEx-d/XP
55
52020431
Aluminium housing, ½ NPT, not for EEx-d/XP
12
52020440
Mounting set housing/sensor consisting of: 2 O-rings 45.69 x 2.62 EPDM + locking
piston
13
52024110
Adjustment keys for adjustment from outside, consisting of: keys, covers and screws
(version 2.0)
15
52020760
Cable gland M20 x 1.5; seal
15
52020761
Cable gland G½, seal, adapter
15
52020762
Plug 2/7-pole, Han7D, seal
15
52020763
Plug 3-pole, M12, seal
20
52020432
Cover for Aluminium housing incl. seal, not for EEx-d/XP
20
52020433
Cover for Aluminium housing incl. seal, for EEx-d/XP
20
52020494
Cover for Aluminium housing with inspection glass incl. seal, for Ex-free area
20
52020492
Cover for Aluminium housing with inspection glass incl. seal, not for EEx-d/XP
20
52020493
Cover for Aluminium housing with inspection glass incl. seal, for EEx-d/XP
21
52020429
Seal set EPDM for cover Aluminium housing (5 pcs.)
25
52020432
Cover for Aluminium housing incl. seal, not for EEx-d/XP
25
52020433
Cover for Aluminium housing incl. seal, for EEx-d/XP
30
52024400
Electronics 4 … 20 mA, HART, Ex, version 2.0x, adjustment keys on electronics
30
52024111
Electronics 4 … 20 mA, HART, Ex, version 2.0x, adjustment keys on the housing
31
52027785
Data memory module
35
52020434
Terminal 3-pole, RFI filter 4 … 20 mA/HART
40
71002865
Indicating module HART with 3 adjustment keys, incl. holder
24
Service instructions VEGADIF 55
Maintenance and fault rectification
31732
-EN