VEGA VEGADIF 55 Service instructions User Manual
Page 10

Code
Message
type/NA
64
Message/De-
scription
Cause
Measure
Priority
702 (W702) Warning C
C> Memory
module data
faulty
l
The data were not
written correctly into
the memory module,
e.g. if the memory
module was removed
during a writing oper-
ation
l
Data memory module
contains no data
l
Repeat upload
l
Carry out reset (Code
7864) and make a
fresh adjustment
l
Copy suitable data in-
to the data memory
module (see operating
instructions manual
VEGADIF 55, chapter
"C
opy configuration
data")
55
703 (W703) Alarm B
B> Measure-
ment transmis-
sion error
l
Fault in the main elec-
tronics
l
Main electronics de-
fective
l
Separate instrument
briefly from voltage
supply
l
Exchange the main
electronics
22
704 (W704) Alarm B
B> Measure-
ment transmis-
sion error
l
Fault in the main elec-
tronics
l
Main electronics de-
fective
l
Separate instrument
briefly from voltage
supply
l
Exchange the main
electronics
12
705 (W705) Alarm B
B> Measure-
ment transmis-
sion error
l
Fault in the main elec-
tronics
l
Main electronics de-
fective
l
Separate instrument
briefly from voltage
supply
l
Exchange the main
electronics
12
10
Service instructions VEGADIF 55
Maintenance and fault rectification
31732
-EN
-080430