Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar

C

able entry/plug

3)

-

S

ingle chamber housing

l

1

x cable gland M20 x 1.5 (cable: ø 5 … 9 mm),

1

x blind stopper M20 x 1.5

or:

l

1

x closing cap M20 x 1.5; 1 x blind stopper

M

20

x 1.5

or:

l

1

x closing cap ½ NPT, 1 x blind plug ½ NPT

or:

l

1

x plug (depending on the version), 1 x blind

stopper M20 x 1.5

-

D

ouble chamber housing

l

1

x cable entry M20 x 1.5 (cable: ø 5 … 9 mm),

1

x blind stopper M20 x 1.5; 1 x blind stopper

M

16

x 1.5 or optionally available with 1 x plug

M

12

x 1 for external indicating and adjustment

unit

or:

l

1

x closing cap ½ NPT, 1 x blind stopper

½ NPT

,

1

x blind stopper M16 x 1.5 or

optionally 1 x plug M12 x 1 for external
indicating and adjustment unit

or:

l

1

x plug (depending on the version), 1 x blind

stopper M20 x 1.5; 1 x blind stopper M16 x 1.5
or optionally available with 1 x plug M12 x 1 for
external indicating and adjustment unit

S

pring-loaded terminals for wire cross-sec-

tion

<

2.5

mm² (AWG 14)

Electromechanical data - version IP 66/IP 68 (1 bar)

C

able entry

-

S

ingle chamber housing

1

x IP 68 cable gland M20 x 1.5; 1 x blind stopper

M

20

x 1.5

-

D

ouble chamber housing

1

x IP 68 cable gland M20 x 1.5; 1 x blind stopper

M

20

x 1.5; 1 x blind stopper M16 x 1.5

C

onnection cable

-

W

ire cross-section

0.5

mm² (AWG 20)

-

W

ire resistance

<

0.036 Ω/

m

-

T

ensile strength

<

1200 N (270

lbf)

-

S

tandard length

5

m (16.4 ft)

-

M

ax. length

1000

m (3280 ft)

3)

D

epending on the version M12 x 1, according to DIN 43650, Harting, 7/

8" FF.

54

VEGAFLEX

67 • 4 … 20

mA/HART - two-wire

10 S

upplement

32311

-EN