VEGA VEGASWING 61 - two-wire User Manual
Page 32
32
9 Supplement
VEGASWING 61 • - two-wire
29227-EN-130409
1
2
-50 °C
(-58 °F)
0 °C
(32 °F)
50 °C
(122 °F)
100 °C
(212 °F)
150 °C
(302 °F)
200 °C
(392 °F)
250 °C
(482 °F)
20
(290)
-1 (-14,5)
40
(580)
64
(928)
Fig. 43: Process temperature - Process pressure with switch position 0.5 g/cm³ (sensitivity switch)
1 Process pressure in bar (psig)
2 Process temperature in °C (°F)
Viscosity - dynamic
0.1 … 10000 mPa s (requirement: with density 1)
Flow velocity
max. 6 m/s (with a viscosity of 10000 mPa s)
Density
0.7 … 2.5 g/cm³ (0.025 … 0.09 lbs/in³); 0.5 … 2.5 g/cm³
(0.018 … 0.09 lbs/in³) by switching over
Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
Cable entry/plug
3)
Ʋ Single chamber housing
– 1 x cable gland M20 x 1.5 (cable: ø 5 … 9 mm), 1 x
blind plug M20 x 1.5
or:
– 1 x closing cap ½ NPT, 1 x blind plug ½ NPT
or:
– 1␣x plug (depending on the version), 1␣x blind stopper
M20␣x␣1.5
Screw terminals
for wire cross-section up to 1.5 mm² (AWG 16)
Electromechanical data - version IP 66/IP 68 (1 bar)
Cable entry
Ʋ Single chamber housing
– 1 x IP 68 cable gland M20 x 1.5; 1 x blind plug
M20 x 1.5
or:
– 1 x closing cap ½ NPT, 1 x blind plug ½ NPT
Connection cable
Ʋ Wire cross-section
0.5 mm² (AWG 20)
Ʋ Wire resistance
< 0.036 Ω/m (0.011 Ω/ft)
Ʋ Tensile strength
< 1200 N (270 lbf)
Ʋ Standard length
5 m (16.4 ft)
Ʋ Max. length
1000 m (3280 ft)
Ʋ Min. bending radius
25 mm (0.984 in) with 25 °C (77 °F)
Ʋ Diameter approx.
8 mm (0.315 in)
3)
Depending on the version M12 x 1, according to ISO 4400, Harting, 7/8" FF.