VEGA VEGAPULS 62 (≥ 2.0.0 - ≤ 3.8) Foundation Fieldbus User Manual
Page 62
-
Diameter approx.
8 mm (0.315 in)
-
Colour - standard PE
Black
-
Colour - standard PUR
Blue
-
Colour - Ex-version
Blue
Indicating and adjustment module
Voltage supply and data transmission
through the sensor
Indication
LC display in dot matrix
Adjustment elements
4 keys
Protection
-
unassembled
IP
20
-
mounted into the sensor without cover
IP
40
Materials
-
Housing
ABS
-
Inspection window
Polyester foil
Power supply
Operating voltage
-
Non-Ex instrument
9 … 32 V DC
-
EEx-ia instrument
9 … 24 V DC
-
EEx-d instrument
16 … 32 V DC
Operating voltage with lighted indicating and adjustment module
-
Non-Ex instrument
12 … 32 V DC
-
EEx-ia instrument
12 … 24 V DC
-
EEx-d instrument
20 … 32 V DC
Power supply by/max. number of sensors
-
H
1 power supply
max. 32 (max. 10 with Ex)
Electrical protective measures
Protection, depending on housing version
-
Plastic housing
IP
66/IP 67
-
Aluminium housing, stainless steel
housing - investment casting, stainless
steel housing - electro-polished
IP
66/IP 68 (0.2 bar)
10)
-
Aluminium and stainless housing, in-
vestment casting (optionally available)
IP
66/IP 68 (1 bar)
Overvoltage category
III
Protection class
II
10)
A suitable cable is the prerequisite for maintaining the protection class.
62
VEGAPULS
62 • Foundation Fieldbus
10 Supplement
28450
-EN
-090305