VEGA VEGAPULS 62 (≥ 2.0.0 - ≤ 3.8) Foundation Fieldbus User Manual
Page 56
Channel Numbers
-
Channel 1
Primary value
-
Channel 2
Secondary value 1
-
Channel 3
Secondary value 2
Transmission rate
31.25 Kbit/s
Current value
10 mA, ±0.5 mA
Damping (63 % of the input variable)
0 … 999 s, adjustable
Input variable
Measured value
distance between process fitting and product sur-
face
Min. distance from antenna end
50 mm (1.969 in)
Recommended meas. range depending on the antenna diameter
-
ø
40 mm (1.575 in)
up to 10 m (32.81 ft)
-
ø
48 mm (1.89 in)
up to 15 m (49.21 ft)
-
ø
75 mm (2.953 in), ø 95 mm (3.74 in),
parabolic antenna
up to 30 m (98.43 ft)
Max. measuring range
up to 35 m (114.83 ft)
Reference conditions to measuring accuracy (similar to DIN EN 60770-1)
Reference conditions according to DIN EN 61298-1
-
Temperature
+18
… +30 °C (+64 … +86 °F)
-
Relative humidity
45 … 75 %
-
Air pressure
860 … 1060 mbar/86 … 106 kPa (12.5 … 15.4 psig)
Other reference conditions
-
Reflector
ideal reflector, e.g. metal plate 2 x 2 m
-
False reflections
Biggest false echo, 20 dB smaller than the useful
echo
Characteristics and performance data
Frequency
K-band (26 GHz technology)
Meas. interval approx.
1 s
Beam angle -3 dB with horn antenna, depending on antenna diameter
-
ø
40 mm (1.575 in)
22°
-
ø
48 mm (1.89 in)
18°
-
ø
75 mm (2.953 in)
10°
-
ø
95 mm (3.74 in)
8°
Beam angle -3 dB with parabolic antenna
4°
56
VEGAPULS
62 • Foundation Fieldbus
10 Supplement
28450
-EN
-090305