beautypg.com

VEGA VEGAPULS 62 (≥ 2.0.0 - ≤ 3.8) Foundation Fieldbus User Manual

Page 57

background image

Step response or adjustment time

5)

< 1

s (dependent on the parameter settings)

Max. level change

Adjustable up to 1 m/min. (dependent on the
parameter adjustment)

Max. emitted HF power of the antenna system

-

Pulse peak power

< 2

mW

-

Pulse duration

< 2

ns

-

Average power

< 5 µW

-

Average power with 1 m distance

< 200

nW/cm

2

Max. emitted HF power of the antenna system - Version with increased sensitivity

-

Pulse peak power

< 10

mW

-

Pulse duration

< 2

ns

-

Average power

< 25 µW

-

Average power with 1 m distance

< 1 µW/

cm

2

Measuring accuracy

Resolution, general

< 1

mm (0.039 in)

Deviation

6)

see diagrams

0,5 m (1.6 ft)

30 m (98.43 ft)

10 mm (0.394 in)

3 mm (0.116 in)

- 3 mm (- 0.116 in)

- 10 mm (- 0.394 in)

0

Fig. 37: Deviation VEGAPULS 62 with horn antenna

5)

Time to output the correct level (with max. 10 % deviation) after a sudden
level change.

6)

Incl. non-linearity, hysteresis and non-repeatability.

VEGAPULS

62 • Foundation Fieldbus

57

10 Supplement

28450

-

EN

-090305