5 technical data – VEGA VEGAFLEX 52V User Manual
Page 9
VEGAFLEX 51V and 52V
9
Product description / Technical data
1.5 Technical data
Power supply
Supply voltage
from signal conditioning instrument VEGAMET
or from the processing system VEGALOG 571
(max. 36 v DC)
fuse 0,5 A (slow-blow)
Current consumption
max. 22,5 mA
Power consumption
max. 80 mW, 0,45 VA
Measuring range
VEGAFLEX 51
0,3 … 10 m
VEGAFLEX 52
0,3 ... 20 m
Output signal
Digital measuring signal (VBUS)
Adjustment
- signal conditioning instruments VEGAMET 514V, 515V, 614V
- PC and adjustment software VEGA Visual Operating
- adjustment module MINICOM
Accuracy
(under reference conditions acc. to IEC 770 - relating to the max. meas. range)
Linearity error
< 0,1 %
Temperature drift
0,015 %/10 K
Resolution
1 mm
Characteristics
Min. span between full and empty adjustment
- digital output signal
10 mm
Ambient conditions
Vessel pressure
-1 … 16 bar
Ambient temperature on the housing
-40
°
C … +60
°
C
Process temperature
-40
°
C … +120
°
C
Storage and transport temperature
-40
°
C … +80
°
C
Protection
IP 66/IP 67 (meets both protections)
Protection class
- two-wire sensor
II
Overvoltage category
III
Max. tensile load
cable
→
4 mm 5 KN
cable
→
8 mm 20 KN
Ex-technical data
Dust-Ex
Zone 10
The permissible operating data of the VEGAFLEX-sensors for dust-Ex-areas are stated in
the certificate.