beautypg.com

Version with plastic housing, Electrical connection – VEGA VEGAPULS 51K…54K 4 … 20 mA; HART compact sensor User Manual

Page 28

background image

28

VEGAPULS 51K … 54K

21750-EN-031222

+

-

+

-

2.23274

1

(+) L1

2

Communication

8

7

6

5

Display

4-20mA

4-

+3

N

-

OK

+

ESC

Tank 1
m (d)
12.345

+

-

Display

5

6

7

8

Communication

2 -

+

4-20mA

1

2.23272

-

OK

+

ESC

Tank 1
m (d)
12.345

Electrical connection

Power supply
4 … 20 mA (passive)

1)

To the indicating instrument in the
sensor lid or to the external indicating
instrument VEGADIS 50

Sockets for connection of
the HART

®

handheld or

the VEGACONNECT

Two-wire technology in
plastic housing

(loop powered)

Four-wire technology in
plastic housing

(separate supply)

Power supply

4 … 20 mA (active)

2)

Terminals
(max. 2.5 mm

2

wire cross-section)

Opening
tabs

Pluggable
adjustment
module
MINICOM

1)

4 … 20 mA passive means that the sensor
consumes a level-dependent current of
4 … 20 mA (consumer).

2)

4 … 20 mA active means that the sensor provides
a level-dependent current of 4 … 20 mA (current
source).

Version with plastic housing

Cable entry
M20 x 1.5

To the display in the lid or
the external indicating
instrument