beautypg.com

VEGA VEGAFLEX 51K User Manual

Page 9

background image

VEGAFLEX 51K

9

Product description

Adjustment

- PC and adjustment software VEGA Visual Operating
- adjustment module MINICOM
- HART

®

handheld

Accuracy (under reference conditions acc. to IEC 770 - relating to the max. meas. range)

Linearity error

< 0.1 %

Temperature drift

0.015 %/10 K

Resolution of the 4 … 20 mA signal

0.025 % of range (DA converter)

Resolution

1 mm

Characteristics

Min. span between
full and empty adjustment
- analogue output signal

10 mm

Ambient conditions

Vessel pressure

-1 … 16 bar

Ambient temperature on the housing

-40°C … +60°C

Process temperature

-40°C … +120°C

Storage and transport temperature

-40°C … +80°C

Protection

IP 66/IP 67 (meets both protection standards)

Protection class
- two-wire sensor

II

- four-wire sensor

I

Overvoltage category

III

Max. tensile load

cable ø

4 mm: 10 KN (check the max. tensile

load of the silo ceiling)

Process fittings

VEGAFLEX 51

G 1

1

/

2

A, 1

1

/

2

“ NPT

steel chromized or 1.4301 (stainless steel)

Ex technical data

StEx

zone 10 (only two-wire sensors)

Ex-Zone 0 acc. to PTB and ATEX II 1/2 G
The permissible operating data of the VEGAFLEX sensors for Ex or StEx areas are listed in
the certificate.

Materials

Housing

PBT (Valox) or
aluminium (powder-coated)

Cable

1.4401 (stainless steel; 316) or
galvanized steel - PA-coated