VEGA VEGAFLEX 51K User Manual
Page 9
VEGAFLEX 51K
9
Product description
Adjustment
- PC and adjustment software VEGA Visual Operating
- adjustment module MINICOM
- HART
®
handheld
Accuracy (under reference conditions acc. to IEC 770 - relating to the max. meas. range)
Linearity error
< 0.1 %
Temperature drift
0.015 %/10 K
Resolution of the 4 … 20 mA signal
0.025 % of range (DA converter)
Resolution
1 mm
Characteristics
Min. span between
full and empty adjustment
- analogue output signal
10 mm
Ambient conditions
Vessel pressure
-1 … 16 bar
Ambient temperature on the housing
-40°C … +60°C
Process temperature
-40°C … +120°C
Storage and transport temperature
-40°C … +80°C
Protection
IP 66/IP 67 (meets both protection standards)
Protection class
- two-wire sensor
II
- four-wire sensor
I
Overvoltage category
III
Max. tensile load
cable ø
4 mm: 10 KN (check the max. tensile
load of the silo ceiling)
Process fittings
VEGAFLEX 51
G 1
1
/
2
A, 1
1
/
2
“ NPT
steel chromized or 1.4301 (stainless steel)
Ex technical data
StEx
zone 10 (only two-wire sensors)
Ex-Zone 0 acc. to PTB and ATEX II 1/2 G
The permissible operating data of the VEGAFLEX sensors for Ex or StEx areas are listed in
the certificate.
Materials
Housing
PBT (Valox) or
aluminium (powder-coated)
Cable
1.4401 (stainless steel; 316) or
galvanized steel - PA-coated