22
VEGAFLEX 51K
Setup
Ad-
just-
ment
Para-
meter
adjust-
ment
Sensor
m(d)
4.700
w.o.
medium
Ad-
just-
ment
in
m(d)
0.0 %
at
m (d)
XX.XXX
(min. adjustment)
OK
OK
OK
OK
with
medium
Min.
adjust
at %
XXX.X
Max.
adjust
at %
XXX.X
1)
1. Adjustment
Under the menu item "
Adjustment“ you inform
the sensor of the measuring range with which
it should work.
1)
In case of two values which can be modified, you
can move with the "+“ key to the second value
(confirm with the "OK“ key).
Adjustment with medium
Fill the vessel e.g. to 10 %, enter in the menu
"
Min-adjustment“ with the "+“ and "–“ keys
10 % and confirm with the "OK“ key. Then fill
the vessel e.g. to 80 % or 100 %, enter in the
menu "
Max-adjustment“ with the "+“ and "–“
keys 80 % or 100 % and confirm with the
"OK“ key.
You can carry out the adjustment with or
without medium. Generally, you will carry out
the adjustment without medium, as you can
adjust without vessel filling.
Adjustment without medium
• Enter the distance of your sensor to the
medium at 0 % (example: 5.850 m) with the
"
+“ and "–“ key.
If you do not know the distance, you have
to do a sounding.
• Enter the distance to the medium your
sensor has at 100 % filling.
Max.
Min.
100 % (distance to the product
0.300 m) corresponds to
1200 liters, e.g. 20 mA
Meas. range
0 % (distance to the product
5.850 m) corresponds to
456 liters, e.g. 4 mA)