4.2 Orientation

Verify the proper sensor orientation by checking for an
“-H” (horizontal piping) or a “-V” (vertical piping) in the
model number on the Verabar name plate.

4.2.1 Horizontal Piping

For air or gas installations, mount the Verabar in the
upper 160° of the pipe to allow any condensate to drain
into the pipe (Figure 1). For liquid or steam installa-
tions, mount the Verabar in the lower 160° of the pipe.
This allows any entrained air to bleed back into the pipe
for liquid applications and allows condensate to collect
in the instrument piping for steam applications.

4.2.2 Vertical Piping

The Verabar may be mounted in any location around
the circumference of the pipe for vertical piping
applications.
















Figure 1. Verabar Orientation in Horizontal Pipe

4.3 DP Transmitter/Local Indicator

Location

When choosing a Verabar location, consider the DP
transmitter/local indicator location:

• The transmitter must be mounted below the

Verabar for liquid and steam applications.

• The transmitter must be mounted above the

Verabar for air and gas applications.

4.4

Installation Drawings and Bill of
Materials

Additional information is available in the Installation
Drawings and Bill of Materials VB-7061 (also on the
VeraData CD). It contains standard and alternate
transmitter locations and a complete bill of materials
based on the fluid type and sensor orientation on the
pipe.

5.0 INSTALLATION

PROCEDURE

5.1

Drill Hole in Pipe

• Completely depressurize and drain the pipe prior

to installation of the Verabar.

• Mark the location of the hole through which the

Verabar will be mounted. Use a center punch to
mark the hole to prevent the drill bit from walking
on the pipe.

• Drill the pipe with the proper sized hole per the

following table:

Sensor Size

Hole Dia

V150-05

1/2" (13mm)

V150-10 1”

(25mm)

V150-15 1-1/2”

(38mm)

• Deburr the hole on the inside of the pipe.




















Figure 2. Verabar Model V150