Veris Verabar V450 Spec Sheet User Manual
Verabar, Hot tap models
Hot Tap Models
V450 Low Pressure Hand Insertion
Flanged Components
Differential Pressure Flow Sensors
Verabar
®
The Most Accurate and Reliable Technology
for Measuring Gas, Liquid and Steam…
Developed from aerospace technology, the Verabar
®
averaging pitot flow sensor provides unsurpassed
accuracy and reliability. With its solid, one-piece
construction and bullet shape, the Verabar
makes flow measurement leak proof
and precise.
The unique sensor shape
reduces drag and flow
induced vibration.
The location of the
low-pressure ports
eliminates the potential
for clogging and improves
signal stability.
Model
V450
V450 Hot Tap
Pipe Connection
Flanged
Mounting Type
Flanged ball or gate access valves
• Lowest cost flanged hot tap model
• Installation, insertion & retraction without system shutdown
Features and Benefits
• Hand insertion and retraction for low pressures (no threaded rods)
• Retaining ring loads sensor to the opposite wall
• Can mount to existing flanges or valves
• Low pressure
• Air
Applications
• Stack/flue gas
• Water
• Hydrocarbon and other gases
Special Designs —
• Custom mounting, lengths, materials, instrument connections, etc.
Consult Factory
• Short straight run
Model Specifications
V450
Sensor Code
10
15
Sensor Diameter
7/8” (22mm)
1-3/8” (35mm)
Accuracy
±1% of flow rate; ±0.5% if calibrated
Max Pressure
30 psig (2.1 Bars)
10 psig (0.7 Bars)
Pipe Size
6”- 42”
12”- 60”
(150mm -1050mm)
(300mm -1500mm)
Instrument Connection
1/2” NPT or Direct Mount
Components Furnished
Weld coupling, weldneck flange, access valve, gaskets, studs & nuts
Flange Size
1-1/2”
2”