Velleman К8091 User Manual
Page 13

13
light control
8. Manual light control
The nightlight can be switched on trough the alarm or manually.
When you want to do it manually you can let it light up or down in gradation or
directly to 100% or directly extinguish the light.
Letting the light growing up or down in gradation by holding the middle button
pressed until the desired level is reached.
With a short press you go directly to the maximum or minimum light intensity.
The repeat function of the buzzer will automatically repeat every 8minutes until
the alarm is deactivated by pressing the manual on/off button.
Note: if the light was already illuminated more than 15minutes before the alarm
time, will the alarm-light increase from that point to its maximum.
7. Alarm process
*
alarm time
time
Light at maximum
Buzzer on
* min. 15 minutes
Snooze
Off
8 minutes
Buzzer on
Snooze
. . .
Off
Alarm is switched off
Note: whit a short press after a dimming function the
light will go directly to it's maximum or minimum, the
direction will be equal to the last dimming direction.
SEQUENCE:
light at minimuum
light at maximum
light at maximum
short press
long press
0
max.
light intensity
0
max.
light intensity