Operation – Ohaus DEFENDER 5000 BENCH SCALES Rechargeable Battery Option Manual multi User Manual
Page 8

EN-6 Rechargeable Battery Option Kit
3. OPERATION
Refer to the instruction manual supplied with indicator for operating instructions.
When the rechargeable battery option is installed, the indicator will operate as
follows:
• During the indicator power up process, the display shows
NImMH to indicate that
the rechargeable battery option is installed.
• When the indicator is connected to AC power, charging will occur even when the
indicator is turned off.
• The indicator will automatically switch to battery operation if there is a power
failure or the power cord is disconnected.
• During charging and operation, the charge level is indicated by the segments of
the battery symbol.
• During charging, the battery symbol blinks.
• During operation the battery symbol does not blink.
• When the battery pack is fully discharged, the indicator display momentarily
shows
LO.bAtt and the indicator turns off.
0 % - 5 % charged
5 % - 25 % charged
26 % - 50 % charged
51 % - 75 % charged
76 % - 100 % charged
NOTE: A fully discharged battery may require charging up to 14 hours. A fully
charged battery will operate the indicator for up to 35 hours. The operating
time may be less, depending on usage conditions (backlight usage, number
of load cells, etc.).