beautypg.com

10 by-count function, 11 accumulation (totalize) function – Ohaus RE PRICE COMPUTING COMPACT SCALES Manual User Manual

Page 12

background image

EN-10

RE Series

3. If set to store two PLU’s per M-key, press and hold the desired

M-

key until the long beep, then quickly press the M-key again
within 1 second. “

L2

” appears momentarily to indicate the data

is stored in the second memory location of that M-key.

4.9.2.2 Recalling a PLU from the M-Key
1. Press the

M-key with the pre-stored data. The corresponding

Unit Price/Tare value will be displayed.

2. If set to store two PLU’s per M-key, quick press the

M-key twice

within 1 second. “

L2

” appears momentarily, then the

corresponding Unit Price/Tare value.

Note: If pressing an M-key with no stored data, “

noPLu

” will show

momentarily in the Weight display.

4.10 By-Count Function

The By-Count function is used as reference to calculate the price of non-

weighing items, e.g., the price for 36 pieces when 3 pieces cost a total of
$1.50.
1. Enter the deal quantity (1-99), e.g., “

3

”, then press

[X]. The X

annunciator will turn on to indicate the scale is in the By-Count mode.

2. Enter the deal price, e.g., “

1.50

”, then press

[FIX]. The Unit Price

display will show “

1.50

”.

3. Enter the quantity to be sold, e.g., “

36

”. The resulting total price of

18.00

” is shown in the Total Price display. Keep entering another

quantity as needed.

4. To end the By-Count function and return to normal weighing mode,

press

[C].

4.11 Accumulation (Totalize) Function

The Accumulation function is used to add the Total Price of several
weighings.

4.11.1 Accumulating
1. Perform a pricing transaction as described in Section 4.6.
2. Press

[+]. The displayed Total Price is added to the accumulation

memory, and the

ADD and TOTAL annunciators will turn on.