Appendix – American Magnetics 4Q06250PS-430 High Stability Integrated Power Supply System User Manual
Page 181
Rev. 5
163
Appendix
Power Supply Details
Insulation coordination
Input
Installation Category II
Overvoltage Category II
Output
Installation Category II
Overvoltage Category II
Pollution degree
2
OUTPUT CHARACTERISTICS
1
NOTE 1 - Output characteristics are for a single standalone unit.
Type of stabilizer
Voltage-current, 4-quadrant
Switch mode
Switching frequency
100 KHz
Output Stage
Source adjustment
range
Voltage
-6 V to +6 V
0 to 50°C
Current
-125 A to +125 A
Sink adjustment range
Voltage
-6 V to +6 V
0 to 50°C, recuperated energy is returned to
line
Current
-125 A to +125 A
Voltage stabilization
(voltage mode)
Source effect
±3 mV
Min-max input voltage
Load effect
±6 mV
0-100% load current
Time effect (drift)
±3 mV
0.5 through 24 hours
Temperature
±3 mV/°C
0 to 50°C
Ripple and noise
±120 mV p-p
Includes switching noise
Error sensing
0.1 V per wire
Above rated output
Transient recovery in
voltage mode
Maximum excursion
±300 mV
Nominal voltage, 50% load step
Recovery time
200
μ
sec
Return within 0.1% of set voltage
Isolation
Voltage
100 V
Output to ground
Parallel operation
Master/slave
Maximum of 2 identical units.
Output Stage Protection
Output overvoltage/overcurrent
Recover by setting input power circuit
breaker to off, then on
Input Stage Protection (PFC)
Internal fault
Recover by setting input power circuit
breaker to off, then on
Input circuit breaker overcurrent
Trips circuit breaker to shut off unit
Small signal
Bandwidth
Voltage channel
2 kHz minimum
Into nominal resistive load 10% of rating
Current channel
800 Hz minimum
Into short circuit, 10% of rating
Rise/Fall time
Voltage channel
250/250
μ
Sec
Into nominal resistive load, measured from
10 to 90%, from 0 to ±100% of rating
Current channel
0.5/0.5 mSec
Into short circuit, measured from 10 to 90%,
from 0 to ±100% of rating
GENERAL (ENVIRONMENTAL) CHARACTERISTICS
Temperature
Operating
0 to +50°C
Full rated load
Storage
-20 to +85°C
Cooling
Two internal fans
Exhaust to the rear
Humidity
0 to 95% RH
Non-condensing
Shock
20 g 11 mS ±50% half sine
Non-operating
Vibration
5-10 Hz:
10 mm double amplitude
3 axes, non-operating
10-55 Hz:
2 g
Table A-13.
Model 4Q06125PS Electrical Specifications (Continued)
Specification
Rating / Description
Condition