Readout Operations
DRO 200T
10
Crossfeed Axis
1.
Make sure that the absolute position is displayed.
2.
Machine the diameter.
3.
While the tool is still contacting the
workpiece, press the
ZERO
key for the
appropriate axis, then the
LOCK
AXIS
key. The readout will lock this tool
position in the display, even if you move the tool.
4.
Move the tool away and measure the diameter.
5.
Enter the diameter.
Incremental Zero
From the readout incremental display, press the
ZERO
key. This sets the
incremental display to zero at the current tool position.
Dia = 1.05
Z
1
0
5
ENTER
.
This puts the zero on the
workpiece centerline
ABS
INCR