beautypg.com

ACU-RITE ENC 150 (Old Style) User Manual

Page 5

background image

Use this information to plan your Linear Encoder installation.

• Mount the linear encoders close to machine guide ways to ensure

system accuracy.

• One side of the linear encoder addresses flush mounting surfaces,

and the opposite side addresses offset mounting surfaces.

• If space between the reading head and the mounting surface

exceeds .18”, use a spacer or mounting bracket to reduce space.

• ACU-RITE bracket kit instructions provide step by step installation

proceedures.

• Tolerances of .010” TIR apply to all mounting dimensions.
• Center support mounting surface required for 24” through 60”

linear encoder measuring lengths mounted without a spar.

• Allow clearance for alignment bracket removal.
Alignment brackets must not be removed until instructed.

• Use reading head leveling set screws when surfaces are not flush.
• Reading head bracket required for a space >.18”.

ACU-RITE

®

4

Mounting Information

ENC150

Scale case

Flush

mounting

Offset

mounting

Backup spar

mounting

-A- = Machine Travel

Reading head

B

Equal

Equal

1.826 ±.010 [46.5]

// .010 A

// .010 A

// .010 B

// .010 A

// .010 A

0.0 ± .010

Move bracket past

the cable strain relief

Alignment bracket removal clearance

1.0

[25mm]

1.38

[35mm]

Alignment
bracket

Alignment
bracket

This manual is related to the following products: