• Slide the brackets away from the reading head.
• Remove the alignment brackets and save for future use.
• Insert the encoder into the spar.
• Center the encoder from end to end with the spar.
• Lock in place by tightening the M4 set screws.
• Attach the bracket to the machine.
• Align the reading head mounting holes with the bracket holes.
• Attach head to bracket / Set leveling screws / Secure fasteners.
• To locate the reading head bracket, attach it to the reading head.
• Center the axis and mark the bracket mounting holes.
• Remove the bracket, drill / tap holes for 1/4-20 (M6).
M4 x 8mm set screws
8-32 x 5/8” SHCS
(M4 x 16mm)
Do not tighten prior to adjusting
leveling set screws.
ACU-RITE
®
12
Reading head bracket
(trim 8-32 screw to
length required)
Spar Installation Procedure
ENC 150
Alignment bracket
removal
Slide brackets away from reading
head and cable.