beautypg.com

ACU-RITE ENC 150 (New Style) User Manual

Page 9

background image

Mounting options can be adapted to machine mounting surfaces
using spacers, standoffs, or leveling set screws.

• Measuring length and mechanical configuration of your machine

determine your options.

• Backup spar mounting is an option but not required for lengths

up to 60”.

• Fastener lengths described on this page are included with the

encoder or the backup spar.

• Less than 24” : Use end mounting holes.

• Over 60” : A backup spar is required.

7

ACU-RITE

®

ENC150

Mounting Requirements

1/4-20 x 1” BHCS
& scale washer (supplied)

End hole mounting

1/4-20 x 1/2” BHCS
& spar washer (supplied)

Backup spar mounting

• 24” to 60” : Use end mounting holes with center support.

.94 [23.8]

1/4-20 x 1” BHCS
Typical (supplied)

1/4-20 x 3/4” SHCS

Scale
washer

Center support

End hole mounting
with center support

M4 x 8mm SHSS
(supplied)

Support washer

This manual is related to the following products: