Placement for Maximum Accuracy
AcuRite sensors are sensitive to surrounding environmental conditions. Proper
placement of both the display unit and the sensor are critical to the accuracy
and performance of this product.
Important Placement Guidelines
Display unit and sensor must be within 330ft (100m) of each other.
MAXIMIZE WIRELESS RANGE
Place units away from large metallic items, thick walls, metal surfaces, or other
objects that may limit wireless communication.
PREVENT WIRELESS INTERFERENCE
Place both units at least 3ft (.9m) away from electronic devices (TV, computer,
microwave, radio, etc.).
LOCATE AWAY FROM HEAT SOURCES
Position sensor away from heaters, air conditioners, chimneys, exhaust vents,
asphalt and concrete (surfaces that radiate heat).
LOCATE AWAY FROM HUMIDITY SOURCES
Avoid installing the sensor near pools, spas, or other bodies of water. Water
sources may impact humidity accuracy.
LOCATE AWAY FROM SPRINKLER HEADS
DO NOT install the sensor where it will be sprayed by a sprinkler system. This
impacts rainfall measurement accuracy and may force water inside the sensor.
LOCATE AWAY FROM WIND & RAIN OBSTRUCTIONS
DO NOT mount the sensor with obstructions above it, as this
will impact rainfall measurement. Consider a location that is
a wide open area, with few structures around to ensure
accurate wind speed and direction measurements.
5-in-1 Installation Guidelines
INSTALLATION HEIGHT Mount the sensor at least 5 feet (1.5 meters) off the
ground (higher is better for wind measurement) in an open area. Secure to
fence post, 2ʼx4ʼ wood, 3/4” pipe, etc. (not included)
LEVEL INSTALLATION Use the bubble level on the top of the sensor to ensure
level installation for accurate wind and rain measurement.
SOLAR CELL ORIENTATION Install the sensor with the solar cell facing SOUTH. This
ensures the cell receives as much sun as possible, and orients wind direction.
11
10
5-in-1 Sensor Installation
1. Fasten mounting base (included)
to a post or pole (not included)
using the 4 longer screws
included in the hardware bag.
2. Insert the mounting base into the
hole on the bottom of the sensor.
3. Make sure the arrows on the top
of the sensor are pointed in the
proper direction and the bubble
level is centered. The solar cell
should be facing south to
properly orient the wind
direction vane.
3. Fasten the sensor into the
mounting base using the 2
shorter screws included in the
hardware bag.
The 5-in-1 sensor is now
ready to use.
Visit us online to view installation photos and
video, or learn more about AcuRite technology:
www.AcuRite.com/5in1
SOUTH
(1.5 meters)
NO OBSTRUCTIONS
ABOVE OR AROUND
Display Unit Placement
Place the display unit in a dry area free of dirt and dust. To
ensure accurate temperature measurement, place out of direct
sunlight and away from heat sources or vents. Display unit stands
upright for tabletop use or is wall-mountable.
C
C
View Video
Clear Data Collected During Installation
When installation is complete, clear erroneous data from the display unit by
pressing the “CLEAR TODAY” button, on the back of the display unit inside the
battery compartment. This button will clear data recorded since 12:00am.
Basic Setup is Complete
The 5-in-1 sensor will now synchronize with the display unit. It may take a few
minutes for synchronization to complete. If both or one of the units appear to
be functioning improperly, please refer to the troubleshooting section.
5-in-1 Sensor Placement
The 5-in-1 sensor is designed to remain outdoors all year long.
Choose an open location with no obstructions above or around
the sensor for the most accurate measurements.