beautypg.com

Troubleshooting – AcuRite 01035 Weather Station User Manual

Page 11

background image

21

20

Problem

Possible Solution

Inaccurate

temperature or

humidity

• Make sure both the display unit and 5-in-1 sensor

are placed away from any heat sources or vents

(see page 11).

• Make sure both units are positioned away from

moisture sources (see page 11).

• Make sure 5-in-1 sensor is mounted at least 5ft off

of the ground.

• Calibrate indoor and outdoor temperature and

humidity (see page 20).

Display screen

not working

• Check that the batteries are installed correctly.

Batteries may need to be replaced.

• Check that power adaptor is fully plugged in (if

using power adapter for power source).

• Reset the display by pressing the reset button,

located on the back of the display unit. Date and

time will need to be entered after a reset.

No rainfall

• Check to ensure the rain gauge stabilizer (plastic

tab) has been removed from the bottom of the

sensor (see page 7).

• Clear debris, such as leaves, out of the rain

collector funnel and debris screen.

• Calibrate the Rain Gauge (see page 21).

Inaccurate wind

readings

• What is wind reading being compared to? Pro

weather stations are typically mounted at 30ft

high or more. Make sure to compare data using

a sensor positioned at the same mounting height

and within the same general vicinity.

• Check location of the sensor. Ensure itʼs

mounted a minimum of 5ft in the air with no

obstructions around it (within several feet).

•Ensure wind cups are spinning freely. If they

hesitate or stop try lubricating with graphite

powder or spray lubricant.

USB connectivity

not working

• Ensure USB cable is securely connected to the

display unit AND to PC USB port.

• Confirm that the correct mode is selected (see

page 13).

Troubleshooting

PC Connect software

data is different than

display unit data

• Check that the USB cable is securely connected to

the display unit AND to your PC USB port.

• Confirm that the correct USB mode is selected on

your display unit.

• Restart the PC Connect Software.

• Unplug the USB cable from your PC for about 1

minute, re-insert.

• USB port may be malfunctioning, try another USB

port.

• USB cable may be malfunctioning, try another

USB cable.

If your AcuRite product does not operate properly after trying

the troubleshooting steps, visit www.AcuRite.com or call

(877) 221-1252 for assistance.

Problem

Possible Solution

Cannot access data

online or on the

Acu-Link mobile app

• Confirm the status readout in PC Connect software

on your PC indicates that data was uploaded OK.

• Make certain you created an account or logged

into your existing account on www.acu-link.com,

and that you have setup your display unit MAC

ADDRESS online, as well.

• Check that the USB cable is securely connected to

the display unit AND to your PC USB port.

• Make certain the display unit is powered on.

• Make certain the PC your display unit is

connected to is always powered on.

• Make certain the PC your display unit is

connected to is always connected to the internet.

• Confirm the display unit USB mode is 3 or 4.

• Confirm your display unit MAC ADDRESS is

entered into the “UPLOAD” window correctly in

the PC Connect Software on your PC.

• Confirm that the “ENABLE” box is checked in the

“UPLOAD” window in the PC Connect Software

on your PC.

• Confirm your display unitʼs MAC ADDRESS is

correct in your account at www.acu-link.com and

on the Acu-Link mobile app.

• Restart the PC Connect Software.

• Restart your PC.

Troubleshooting