Figure 21 d-sub plug assembly, D. cockpit remote switch 9-pin plug installation, E. wiring installation – ACR&Artex ME406 ACE ELT User Manual
Page 64: G. see figure 21 d-sub
ARTEX PRODUCTS / ACR ELECTRONICS, INC
DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL
ME406 (453-6603), ME406HM (453-6604)
25-62-30
Page 64 of 84
May 03/13
(12) Install the strain relief clamp.
Figure 21 D-Sub Plug Assembly
SUBTASK 25-62-30-450-003
D. Cockpit Remote Switch 9-Pin Plug Installation
NOTE: If moisture intrusion is a possibility, apply a thin bead of RTV over rear of the MOLEX
connector to prevent corrosion buildup. Use Dow Corning RTV-3145 or equivalent.
(1)
Insert the wiring pins in the Molex 9-pin cockpit remote switch plug (151-5009), referring to
the wiring diagram appropriate for the installation, as follows:
(a)
Insert each harness female pin into the plug, referring to the wire identification and pin
relationships recorded in Step C.(5)(a).
NOTE: Terminal pins may be removed from the plug using Molex extraction tool
11030002, or equivalent.
(b)
Insert the remote switch power wire female pin into Pin 1 or Pin 3 of the plug, as
appropriate for the selected 14V or 28V power source.
(c)
Insert the remote switch ground wire into Pin 9 of the plug.
SUBTASK 25-62-30-450-004
E.
Wiring Installation
(1)
Route the remote switch harness wire bundle and breakout wiring through the airframe.
GROMMET
(RAISED COLLAR END)
4 OR 5-CONDUCTOR CABLE
(HORN CONDUCTOR NOT
SHOWN)
THUMBSCREW (TYP.)
BRACKET WASHER (TYP.)
HOUSING HALF (TYP.)
HARDWARE (TYP.)
15-PIN
D-SUB PLUG
NOTE: STRAIN RELIEF
CLAMP NOT SHOWN