Figure 3 remote switch front view, Figure 4 buzzer, Figure 5 battery pack assembly – ACR&Artex ME406 ACE ELT User Manual
Page 24
ARTEX PRODUCTS / ACR ELECTRONICS, INC
DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL
ME406 (453-6603), ME406HM (453-6604)
25-62-30
Page 24 of 84
May 03/13
(2)
The cockpit-mounted remote switch assembly is comprised of an ELT status LED and control
switch, and allows an operator to manually turn the ELT on (i.e., activate) for testing and
reset (i.e., deactivate) the ELT. See Figure 3 Remote Switch Front View.
NOTE: The ELT CANNOT be disarmed or disabled from the cockpit. Cockpit operation is
limited to deactivating or manually activating the ELT.
Figure 3 Remote Switch Front View
(3)
The buzzer (i.e., horn) provides an audible alert when the ELT is active. See Figure 4 Buzzer.
Figure 4 Buzzer
(4)
The battery pack for the ME406 Series ELT consists of two “D” size lithium manganese dioxide
cells connected in series. To prevent the cells from being charged, diodes are connected
across each cell and fuses are connected to the output. See Figure 5 Battery Pack Assembly.
Figure 5 Battery Pack Assembly
ARTEX
ON
ARM
Press ON
Wait 1 Second
Press ARM
EMERGENCY USE ONL
Y
Test/Reset
ELT
LED