English – Vitek VT-1510 SR User Manual
Page 9
9
ENGLISH
• Unplug power cord from wall outlet and wait until coffee machine is cooled down com-
pletely.
• Install percolator-filer (b) to its place, and tighten fastening screw (a) by screwdriver
rotating it anticlockwise.
CLEANING
Wipe the body of the coffee maker with a damp soft cloth. Do not use abrasives and metal
sponges.
Do not immerse the body of the coffee maker into water or other liquids
Wash the removable parts of the coffee maker in warm water with a soft detergent, rinse
and dry.
Water tray (1)
• Remove the grid (2) from the tray (1), remove the tray (1) from the base and pour water
from the tray (1) set the tray (1) on its place, set the grid (2) on the tray (1). If necessary
you can wash the tray (1) and the grid (2) in warm water with a soft detergent, rinse and
dry.
PROBLEMS, THEIR CAUSES AND SOLUTIONS:
Problem
Cause
Solution
“Espresso”
Is not hot enough
Cups, and the filter holder (3) were
cold.
Heat the accessories preliminary
(Cups and the filter holder). See
the “Making espresso” chapter
The filter holder (3) is set improp-
erly and not until bumping.
See the “Making espresso” chap-
ter
Coffee leakage
from the filter holder
(3)
Coffee grouts on the sides of the
filter.
Clean the filter sides.
The gasket (3) is damaged.
Apply to the authorized service
center.
No water in the water tank (9).
Fill the water tank (9) with water.
When water supply
is switched on, the
pump produces
noise
The water tank (9) is set improp-
erly.
Press on the tank (9) above to set
it on its place.
Ground coffee is too dry, and the
pump can not produce necessary
pressure
Use freshly ground coffee.
No water in the water tank (9).
Fill the water tank (9) with water.
The water tank (9) is set improp-
erly.
Press on the tank (9) above to set
it on its place.
1510.indd 9
1510.indd 9
02.04.2008 15:43:59
02.04.2008 15:43:59