17

HDE 13 RQX

HDE 10 RQX

HDE 6 RQ

........ 950 W .................. 725 W ..................725 W

........ 475 W .................. 362 W ..................362 W

..... 0-900 min

-1

.........0-1200 min

-1

.........0-4200 min

-1

..... 0-550 min

-1

...........0-795 min

-1

.........0-2680 min

-1

.......... 13 mm .................. 10 mm ....................6 mm

.......... 38 mm .................. 30 mm ..................16 mm

.......... 20 mm .................. 13 mm ....................8 mm

.... 1,5-13 mm ............1,0-10 mm ............1,0-10 mm

.. 1/2"x20 ................1/2"x20 ................3/8"x24

......... 2,0 kg ................... 1,9 kg ...................1,4 kg

.......... 99 dB (A) ............. 99 dB (A) ..............99 dB (A)

.........110 dB (A) ........... 110 dB (A) ............110 dB (A)

......... 5,4 m/s

2

................ 2,7 m/s

2

................6,8 m/s

2

......... 1,5 m/s

2

................ 1,5 m/s

2

................1,5 m/s

2

ENGLISH

TECHNICAL DATA

Rated input .............................................................................

Output .....................................................................................

No-load speed ........................................................................

Speed under load max. ..........................................................

Drilling capacity in steel ..........................................................

Drilling capacity in soft- wood .................................................

Drilling capacity in Aluminium .................................................

Drill opening range .................................................................

Drive shank.............................................................................

Weight according EPTA-Procedure 01/2003 ..........................

Noise information

Measured values determined according to EN 60745.

Typically, the A-weighted noise levels of the tool are:

Sound pressure level (K = 3 dB(A)) ......................................

Sound power level (K = 3 dB(A)) ...........................................

Wear ear protectors!
Vibration information

Total vibration values (vector sum in the three axes)

determined according to EN 60745.

Vibration emission value a

h

....................................................

Uncertainty K ..........................................................................

WARNING! Read all safety warnings and all

instructions, including those given in the accompanying

brochure. Failure to follow the warnings and instructions

may result in electric shock, fire and/or serious injury.

Save all warnings and instructions for future reference.

SAFETY INSTRUCTIONS

Wear ear protectors. Exposure to noise can cause hearing

loss.
Use auxiliary handles supplied with the tool. Loss of

control can cause personal injury.Appliances used at many

different locations including open air must be connected via

a current surge preventing switch.
Hold power tool by insulated gripping surfaces, when

performing an operation where the cutting accessory

may contact hidden wiring or its own cord. Contact with

a „live“ wire will also make exposed metal parts of the power

tool „live“ and shock the operator.
Appliances used at many different locations including open

air should be connected via a residual current device of

30 mA or less.
Use protective equipment. Always wear safety glasses when

working with the machine. The use of protective clothing is

recommended, such as dust mask, protective gloves, sturdy

non-slip footwear, helmet and ear defenders.
Always wear goggles when using the machine. It is

recommended to wear gloves, sturdy non slipping shoes

and apron.
Sawdust and splinters must not be removed while the

machine is running.

Always disconnect the plug from the socket before carrying

out any work on the machine.
Only plug-in when machine is switched off.
Keep mains lead clear from working range of the machine.

Always lead the cable away behind you.
When working with large drill diameters, the auxiliary handle

must be fastened in a right angle with the main handle (see

illustrations, section "Twisting the handle").
When working in walls ceiling, or floor, take care to avoid

electric cables and gas or waterpipes.

EC-DECLARATION OF CONFORMITY

We declare under our sole responsibility that this product is

in conformity with the following standards or standardized

documents.

EN 60745-1:2009 + A11:2010

EN 60745-2-1:2010

EN 55014-1:2006 + A1:2009 + A2:2011

EN 55014-2:1997 + A1:2001 + A2:2008

EN 61000-3-2:2006 + A1:2009 + A2:2009

EN 61000-3-3:2008

in accordance with the regulations

2011/65/EU (RoHs)

2006/42/EC

2004/108/EC

Winnenden, 2012-09-12

ENGLISH

WARNING
The vibration emission level given in this information sheet has been measured in accordance with a standardised test given

in EN 60745 and may be used to compare one tool with another. It may be used for a preliminary assessment of exposure.
The declared vibration emission level represents the main applications of the tool. However if the tool is used for different

applications, with different accessories or poorly maintained, the vibration emission may differ. This may significantly increase

the exposure level over the total working period.
An estimation of the level of exposure to vibration should also take into account the times when the tool is switched off or

when it is running but not actually doing the job. This may significantly reduce the exposure level over the total working period.
Identify additional safety measures to protect the operator from the effects of vibration such as: maintain the tool and the

accessories, keep the hands warm, organisation of work patterns.

Rainer Kumpf

Director Product Development
Authorized to compile the technical file

SPECIFIED CONDITIONS OF USE

The drill can be used for drilling in wood, metal and plastics

and for screwdriving.
Do not use this product in any other way as stated for

normal use.

MAINS CONNECTION

Connect only to single-phase a.c. current and only to the

system voltage indicated on the rating plate. It is also

possible to connect to sockets without an earthing contact

as the design conforms to safety class II.

MAINTENANCE

The ventilation slots of the machine must be kept clear at all

times.
If the machine is mainly used for percussion drilling,

regularly remove collected dust from the chuck. To remove

the dust hold the machine with the chuck facing down

vertically, and completely open and close the chuck. The

collected dust will fall from the chuck. It is recommended to

regularly use cleaner for the clamping jaws and the

clamping jaw borings.
Use only Milwaukee accessories and Milwaukee spare

parts. Should components need to be replaced which have

not been described, please contact one of our Milwaukee

service agents (see our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered.

Please state the Article No. as well as the machine type

printed on the label and order the drawing at your local

service agents or directly at: Milwaukee Electric Tool,

Max-Eyth-Straße 10, D-71364 Winnenden, Germany.

SYMBOLS

Please read the instructions carefully

before starting the machine.

Always disconnect the plug from the socket

before carrying out any work on the machine.

Accessory - Not included in standard

equipment, available as an accessory.

Always wear goggles when using the

machine.

Do not dispose of electric tools together with

household waste material! In observance of

European Directive 2002/96/EC on waste

electrical and electronic equipment and its

implementation in accordance with national

law, electric tools that have reached the end of

their life must be collected separately and

returned to an environmentally compatible

recycling facility.

Class II construction, tool in which protection

against electric shock does not rely on basic

insulation only, but in which additional safety

precautions, such as double insulation or

reinforced insulation, are provided.