4 modify setting values – “set” command – Edimax Technology PS-3207U User Manual
Page 141

133
9.4 Modify Setting Values
– “set” Command
“set” command is used to modify the setting values of
this pr int ser ver. The for ma t of “s et” c omma nd is as
f ollowing:
se t a r gument_na me va lue
Then the va lue will be wr itte n into the s ys te m
c onf igurat ion . For e xa mple , if you want to set IP addr ess of
the pr int se r ver to 192.168.2.2, type “se t ip 192.168.2 .2”
c omma nd and the I P of the pr int s e rver wil l be changed.
Af ter the s ett ing is f inishe d, please r eboot the pr int s er ver .
admin# se t ip 192.168.2.2
admin# r eboot
If you ente r only “s et” , the s ys te m wil l list a ll
a rguments of “ set” co mma nd and the comma nd for mat .
The following table lists a ll t he a r guments whos e va lue
c an be modif ie d by “se t” comma nd:
Argument
Description
Example
psname
Print server name
set psname PS001
password
Login password
set password 1234
username
Login username
set username admin
wlfunc
Enable or disable the
wireless LAN function.
The value should be
“disabled”, “enabled” or
“auto”
set wlfunc auto
wlmode
Wireless LAN mode is
Infrastructure or Ad Hoc.
The value should be
“inf”
or
“ad hoc”
set wlmode ad hoc
ESSID
ESSID of the wireless LAN set ESSID default