COOLING CAPACITY - With Air Handler Coils

UNIT MODEL

AIR HANDLER

COIL

1

MODEL

COOLING

MODEL

ELECTRIC

2

HEAT KW

W

RATED

CFM

NET MBH

SEER

W/O TXV

SEER

WITH TXV

3

EER

TOTAL SENS.

3 PH 10 SEER HP WITH MA / MC / N-AH / G2FD

E1RA036S(25,46)

MA12BN2,4

10

17

FC/MC35B3X

1250

34.4

25.3

10

8.95

MA12BN2,4

10

17

FC/MC36B3X

1250

34.4

25.3

10

8.95

MA12BN2,4

10

17

FC/MC42B3X

1250

34.4

25.3

10

8.95

N1AHC1646

10, 15

21

G2FD042(S,H)21

1250

34.2

25.3

10

8.95

E2RA048S(25,46

MA16CN4

10, 15

21

FC/MC48C3X

1600

45.5

33.7

10

9.45

MA20DN2

10, 15, 25

24

FC/MC48D3X

1725

45.5

33.7

10

9.45

MA20DN4

10, 15, 29

24

FC/MC48D3X

1725

45.5

33.7

10

9.45

N1AHC1646

10, 15

21

G2FD048(S,H)21

1600

45.5

33.7

10

9.45

N1AHD2046

10, 15, 29

24

G2FD048(S,H)24

1600

45.5

33.7

10

9.45

E1RA060S(25,46)

MA20DN4

10, 15, 29

24

FC/MC60D3X

2000

57.0

41.0

10

9.80

N1AHD2046

10, 15, 29

24

G2FD048(S,H)24

1700

57.0

41.0

10

9.80

3 PH 10 SEER HP WITH AHP / SHP / F2RP / RC / FP / FC

4,5

E1RA036S25

F2RP/FP036

5, 8, 10, 15, 19

21

1250

34.0

24.9

10

9.00

F2RD/FP042

5, 8, 10, 15

21

1250

34.0

25.6

10

9.00

AHP36C3X

10, 15

21

1250

34.0

25.6

10

9.00

AHP42C3X

10, 15, 18

21

1250

34.0

25.6

10

9.00

E2RA048S25

F2FP048

5, 8, 10, 15, 20, 25

24

1600

45.0

33.5

10

9.40

F2FP060

5, 8, 10, 15, 20, 25

24

1600

46.5

34.4

10

9.60

AHP/SHP48D3X

10, 15, 18

24

1600

46.5

34.4

10

9.60

E1RA060S25

F2FP060

5, 8, 10, 15, 20, 25

24

1700

56.0

40.0

10

9.40

AHP/SHP60D3X

10, 15

24

1700

56.0

40.0

10

9.40

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210/240.
Cooling MBH based on 8

0°F entering air temperature, 50% RH, and rated air flow.

KW includes compressor, outdoor fan and indoor blower motor watts. Add-on coils include 365 watts/1000 CFM for blower motor.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input
in watt-hours during the same period.

1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Single phase units require single phase 2HK heaters.

3. TXV = Use 1TV700 Series Kit.

4. To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC

.

models. All ratings remain the same.

5. FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D. standard.