beautypg.com

Physical and electrical data – York 090 User Manual

Page 2

background image

279104-YTG-B-0307

2

Unitary Products Group

All dimensions are in inches. They are subject to change
without notice. Certified dimensions will be provided upon
request.

Physical and Electrical Data

MODEL

E1RA036S25

E2RA048S25

E1RA060S25

E1RA036S46

E2RA048S46

E1RA060S46

Unit Supply Voltage

208/230-3-60

460 - 3 - 60

Normal Voltage Range

1

187 to 252

432 to 504

Minimum Circuit Ampacity

15.0

18.9

24.5

8.0

10.1

12.0

Max. Qvercurrent Device Amps

2

25

30

40

15

15

20

Compressor Type

3

Inertia

Scroll

D

Scroll

C

Inertia

Scroll

D

Scroll

C

Compressor Amps

Rated Load

10.9

14.1

18.6

5.8

7.0

9.0

Locked Rotor

78

125

128

40

55

63

Crankcase Heater

Yes

No

No

Yes

No

No

Fan Motor Amps

Rated Load

1.4

1.3

1.3

.8

.7

.8

Fan Diameter Inches

18

22

24

18

22

24

Fan Motor

Rated HP

1/4

1/4

1/4

1/4

1/5

1/4

Nominal RPM

1,100

850

850

1,100

825

850

Nominal CFM

2,750

3,500

3,100

2,750

3,500

3,100

Coil

Face Area Sq. Ft.

12.58

19.65

18.00

12.58

19.65

18.00

Rows Deep

1

1

2

1

1

2

Fin / Inches

14

13

14

14

13

14

Liquid Line Set OD (Field Installed)

3/8

3/8

3/8

3/8

3/8

3/8

Vapor Line Set OD (Field Installed)

3/4

7/8

7/8

3/4

7/8

7/8

Unit Charge (Lbs. - Oz.)

4

5 - 12

8 - 3

11 - 3

5 - 12

8 - 3

11 - 3

Charge Per Foot, Oz.

.68

.70

.70

.68

.70

.70

Operating Weight Lbs.

178

232

243

178

232

243

1. Rated in accordance with ARI Standard 110, utilization range “A”.
2. Dual element fuses or HACR circuit breaker.
3. All scrolls listed with a superscript “D” are Danfoss scrolls. All scrolls listed with a superscript “C” are Copeland scrolls.
4. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than

15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.

C

A

B

DIMENSIONS

Unit

Model

Dimensions

(Inches)

Refrigerant

Connection

Service Valve Size

A

1

1. Including fan guard.

B

C

Liquid

Vapor

036

25

35

23

3/8”

3/4”

048

33

37

27

7/8”

060

26

43

32

7/8”