Link 2000 remote control panel, Link 2000 remote control panel –7, Remote control wiring – Xantrex Technology 10 User Manual
Page 45: Remote power consumption

Link 2000 Remote Control Panel
975-0251-01-01
3–7
* Default setting.
** Refer to voltages under “Battery Charger Voltage Settings”.
Remote Control Wiring
The remote control panel is supplied with 7.62 m or 15.24 m of RJ11 remote
cable. The cable supplied may have 6 conductors; however, only 4 conductors are
required. You may buy standard 4-conductor telephone cable and run up to
15.24 m if desired. Use only a single length of telephone wire—do not splice.
Remote Power Consumption
Link 2000 Remote Control Panel
The Link 2000 and 2000R offer increased monitoring and control options. In
addition to providing inverter/charger control, the Link 2000 enables precision
monitoring of DC voltage, current, and amp hours for two battery banks.
The Link 2000R adds the ability to control an engine driven alternator. This
precision regulator transforms an alternator into a 3 stage battery charging system
like the charger in the Freedom 10.
If a Link 2000 or 2000R remote is being used to control the inverter/charger, refer
to the Link manual for setup and control information.
Off
Enable: Charger on when
AC connected.*
Idle Sensitivity
5
6
On
On
Idle disabled
Off
On
15 watts
On
Off
6 watts
Off
Off
4 watts*
Power Sharing
7
8
On
On
2 amps
Off
On
5 amps
On
Off
10 amps
Off
Off
15 amps*
Table 3-2 DIP switch function and position summary
Feature
Switch Number
Set Point
Table 3-3 System current consumption versus idle mode
Idle Mode
With Remote
Without Remote
Normal Idle
181 mA
120 mA
Idle Circuit Disabled
496 mA
n/a
Unit Shut Off
16 mA
7 mA